Integrated SAS controller logs SAS_ERR3 error - IBM


AIX and VIOS Users Performing an 'errpt -a' command yields the following result:
LABEL:SAS_ERR3
IDENTIFIER:12296806
Date/Time:(Date and time indicated)
Sequence Number: (Sequence number indicated)
Machine ID:(Machine ID indicated)
Node ID:(Note ID indicated)
Class:H
Type:TEMP
Resource Name:sissas0
Resource Class:adapter
Resource Type:1410c102
Location:U78A5.001.WIH23D3-P1-T5
Vital Product Data (VPD):
Read Only Memory (ROM) Level(alterable).......0320003c
Customer Card ID Number.....57D0
Description
SAS ERROR
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES

Workaround
The workaround is to reconfigure the adapter, which causes the SAS Discovery process to be executed. The devices are then discovered and reported to the system. This workaround can be achieved by performing the following steps:
AIX and VIOS Users:


  Select Diag --> Adv Diag Routines --> System Verification --> sissasX diag --> Task Selection --> Microcode Tasks --> Download Microcode --> sissasX


SUSE or RHEL Users:


  Use the iprconfig command to flash microcode on to the SAS Controller. See the instructions in the microcode README file.